High Sensitivity B Cells (HSB)


Test Name
Lymphocyte Subsets - High Sensitivity B Cells
Test Code
HSBCELL
Specimen Type

Lithium Heparin required and EDTA for an FBE.

Test MUST be set up within 24 hours of collection for results to be reported to <0.1% B cells. Samples set up 24-48hrs are reported to the lower sensitivity of <0.5% B cells.

Minimum Volume

0.5 mL lithium heparin and 0.5mL EDTA for an FBE

Comments

Medical Staff: Please request an FBE as it is required to quantitate absolute values and must be collected at the same time.

Collection Staff: If blood is to be collected Fridays after 12 midday, please call laboratory ext 55725 before collecting specimen.

Specimen Reception/Laboratory: Do not spin. Keep at room temperature.

External Laboratories:
Samples MUST arrive at RCH within 24 hrs of collection. Samples should be collected in the AFTERNOON on Mondays to Thursdays (excluding public holidays) to ensure the samples arrive and are tested within 24 hrs. 

Samples must be kept at room temperature during transportation.

The FBE can be performed locally. Please supply a copy of the FBE result.

Assay Performed
Immunology
RCH
9345 5725
Laboratory Hours: 0800-1730 Mon-Fri (excluding PH)
no after hours service
––
Assay Frequency

Samples may be collected Monday – Friday 12 midday. Please see note above for Friday afternoon pm specimens).

Testing performed Monday – Friday (excluding public holidays).